      Description

      Dear IDAS team, Carlos,

      after the disk failure on our server, we repaired, re-installed, and
      re-started the application that uses the IDAS instance on the
      130.206.80.47:8002 (Idas FINESCE)

      IDASClient c = new
      IDASClient("http://130.206.80.47:8002/idas/sml?apikey=69ra4ia6acvgm6f5p7nn19
      crdi");

      We cross-checked the network settings and the communication channel is open,
      not restricted.

      The issue is the fact that the IDAS refuse the connection by returning the
      "407 Proxy Authentication required".

      We do not have any proxy. Our software worked in the past. There seems no
      reasons for the different behavior.

      We tried to ping http://130.206.80.47, but IDAS is not answering.

      We tried to post some data through POSTMAN, but the answer is "404 Not
      Found".

      The urgency is caused by the 15th September Final review of FIENSCE with EC
      officials, so the application should be working.

      Please, could you check and reactivate the IDAS instance that serves FINESCE
      application as soon as possible in the same configuration as before.

      Thank you. M. SImonov

      _______________________________________________
      Fiware-lab-help mailing list
      Fiware-lab-help@lists.fiware.org
      https://lists.fiware.org/listinfo/fiware-lab-help-new
      [Created via e-mail received from: "M. Simonov, PhD (ISMB)" <simonov@ismb.it>]

      1. signature.asc
        0.2 kB
        Daniele Santoro
      2. signature.asc
        0.2 kB
        Daniele Santoro

        Activity

        Hide
        fw.ext.user FW External User added a comment -

        Hi Massimiliano,

        Our pleasure!

        Good luck with the review and thanks again for using IDAS!

        I close the JIRA ticket.

        BR

        ---------------------------------------------------------------------------
        ---------------------------------------------
        Carlos Ralli Ucendo (carlos.ralliucendo@telefonica.com)
        Cell: +34696923588
        Twitter: @carlosralli
        Blog: http://the-internet6.blogspot.com.es
        <http://the-internet6.blogspot.com.es/>
        Telefónica I+D SAU
        Madrid, Spain
        ---------------------------------------------------------------------------
        ---------------------------------------------
        Follow FIWARE project (Future Internet Services Core Platform):
        Website: http://www.fi-ware. <http://www.fi-ware.eu/>org
        Facebook: http://www.facebook.com/pages/FI-WARE/251366491587242
        Twitter: @fiware
        LinkedIn: http://www.linkedin.com/groups/FIWARE-4239932
        ---------------------------------------------------------------------------
        ---------------------------------------------

        El 10/09/15 12:37, "Massimiliano Nigrelli" <massimiliano.nigrelli@eng.it>

        ________________________________

        Este mensaje y sus adjuntos se dirigen exclusivamente a su destinatario, puede contener información privilegiada o confidencial y es para uso exclusivo de la persona o entidad de destino. Si no es usted. el destinatario indicado, queda notificado de que la lectura, utilización, divulgación y/o copia sin autorización puede estar prohibida en virtud de la legislación vigente. Si ha recibido este mensaje por error, le rogamos que nos lo comunique inmediatamente por esta misma vía y proceda a su destrucción.

        The information contained in this transmission is privileged and confidential information intended only for the use of the individual or entity named above. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this transmission in error, do not read it. Please immediately reply to the sender that you have received this communication in error and then delete it.

        Esta mensagem e seus anexos se dirigem exclusivamente ao seu destinatário, pode conter informação privilegiada ou confidencial e é para uso exclusivo da pessoa ou entidade de destino. Se não é vossa senhoria o destinatário indicado, fica notificado de que a leitura, utilização, divulgação e/ou cópia sem autorização pode estar proibida em virtude da legislação vigente. Se recebeu esta mensagem por erro, rogamos-lhe que nos o comunique imediatamente por esta mesma via e proceda a sua destruição
        _______________________________________________
        Fiware-lab-help mailing list
        Fiware-lab-help@lists.fiware.org
        https://lists.fiware.org/listinfo/fiware-lab-help-new

        Show
        fw.ext.user FW External User added a comment - Hi Massimiliano, Our pleasure! Good luck with the review and thanks again for using IDAS! I close the JIRA ticket. BR – --------------------------------------------------------------------------- --------------------------------------------- Carlos Ralli Ucendo (carlos.ralliucendo@telefonica.com) Cell: +34696923588 Twitter: @carlosralli Blog: http://the-internet6.blogspot.com.es < http://the-internet6.blogspot.com.es/ > Telefónica I+D SAU Madrid, Spain --------------------------------------------------------------------------- --------------------------------------------- Follow FIWARE project (Future Internet Services Core Platform): Website: http://www.fi-ware . < http://www.fi-ware.eu/ >org Facebook: http://www.facebook.com/pages/FI-WARE/251366491587242 Twitter: @fiware LinkedIn: http://www.linkedin.com/groups/FIWARE-4239932 --------------------------------------------------------------------------- --------------------------------------------- El 10/09/15 12:37, "Massimiliano Nigrelli" <massimiliano.nigrelli@eng.it> ________________________________ Este mensaje y sus adjuntos se dirigen exclusivamente a su destinatario, puede contener información privilegiada o confidencial y es para uso exclusivo de la persona o entidad de destino. Si no es usted. el destinatario indicado, queda notificado de que la lectura, utilización, divulgación y/o copia sin autorización puede estar prohibida en virtud de la legislación vigente. Si ha recibido este mensaje por error, le rogamos que nos lo comunique inmediatamente por esta misma vía y proceda a su destrucción. The information contained in this transmission is privileged and confidential information intended only for the use of the individual or entity named above. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this transmission in error, do not read it. Please immediately reply to the sender that you have received this communication in error and then delete it. Esta mensagem e seus anexos se dirigem exclusivamente ao seu destinatário, pode conter informação privilegiada ou confidencial e é para uso exclusivo da pessoa ou entidade de destino. Se não é vossa senhoria o destinatário indicado, fica notificado de que a leitura, utilização, divulgação e/ou cópia sem autorização pode estar proibida em virtude da legislação vigente. Se recebeu esta mensagem por erro, rogamos-lhe que nos o comunique imediatamente por esta mesma via e proceda a sua destruição _______________________________________________ Fiware-lab-help mailing list Fiware-lab-help@lists.fiware.org https://lists.fiware.org/listinfo/fiware-lab-help-new
        Hide
        fw.ext.user FW External User added a comment -

        Dear IDAS team,

        we are sending the data to the IDAS since 10:45AM.
        Now we have to check if the whole chain is working, e.g. whether the data
        pass through and arrives to ORION.

        Thank you very much for the quick reply!

        Yours, Mikhail Simonov

        Show
        fw.ext.user FW External User added a comment - Dear IDAS team, we are sending the data to the IDAS since 10:45AM. Now we have to check if the whole chain is working, e.g. whether the data pass through and arrives to ORION. Thank you very much for the quick reply! Yours, Mikhail Simonov
        Hide
        fw.ext.user FW External User added a comment -

        Dear Massimiliano and FINESCE team,

        I hope your review went quite well including the demonstration.

        If I understood well, this was FINESCE final review, so I think it is the
        right time to bring back a discussion that we already had in the past.

        The fact is that DCA/SBC (the old version of IDAS that you are using) is
        not supported since long time ago (>1 year) but we kept it only for your
        usage, so your could end the project up without disturbing too much.

        Today we really need to take an action on this so we all have two options
        depending on your needs:

        1. If you think FINESCE infrastructure will be down in a reasonable time
        (say 1 month max) we can keep this instance and shut it down by Nov 1st.

        2. If you think you will further be using IDAS you have to upgrade as soon
        as possible to the new architecture based on IoT Agents+ ContextBroker.
        This architecture and components is really stable (we use it in some
        Telefonica commercial projects too) and is extremely easier to use and
        exploit.
        In this preso you have the four easy steps to register and use devices.
        I can configure you a private instance ³finesce² to start testing.
        http://www.slideshare.net/FI-WARE/fiware-iotidasintroul20v2

        Please, let us know your decision so we can proceed.

        Thanks a lot for your cooperation and Thanks for using IDAS!

        ---------------------------------------------------------------------------
        ---------------------------------------------
        Carlos Ralli Ucendo (carlos.ralliucendo@telefonica.com)
        Cell: +34696923588
        Twitter: @carlosralli
        Blog: http://the-internet6.blogspot.com.es
        <http://the-internet6.blogspot.com.es/>
        Telefónica I+D SAU
        Madrid, Spain
        ---------------------------------------------------------------------------
        ---------------------------------------------
        Follow FIWARE project (Future Internet Services Core Platform):
        Website: http://www.fi-ware. <http://www.fi-ware.eu/>org
        Facebook: http://www.facebook.com/pages/FI-WARE/251366491587242
        Twitter: @fiware
        LinkedIn: http://www.linkedin.com/groups/FIWARE-4239932
        ---------------------------------------------------------------------------
        ---------------------------------------------

        El 10/09/15 12:37, "Massimiliano Nigrelli" <massimiliano.nigrelli@eng.it>

        ________________________________

        Este mensaje y sus adjuntos se dirigen exclusivamente a su destinatario, puede contener información privilegiada o confidencial y es para uso exclusivo de la persona o entidad de destino. Si no es usted. el destinatario indicado, queda notificado de que la lectura, utilización, divulgación y/o copia sin autorización puede estar prohibida en virtud de la legislación vigente. Si ha recibido este mensaje por error, le rogamos que nos lo comunique inmediatamente por esta misma vía y proceda a su destrucción.

        The information contained in this transmission is privileged and confidential information intended only for the use of the individual or entity named above. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this transmission in error, do not read it. Please immediately reply to the sender that you have received this communication in error and then delete it.

        Esta mensagem e seus anexos se dirigem exclusivamente ao seu destinatário, pode conter informação privilegiada ou confidencial e é para uso exclusivo da pessoa ou entidade de destino. Se não é vossa senhoria o destinatário indicado, fica notificado de que a leitura, utilização, divulgação e/ou cópia sem autorização pode estar proibida em virtude da legislação vigente. Se recebeu esta mensagem por erro, rogamos-lhe que nos o comunique imediatamente por esta mesma via e proceda a sua destruição
        _______________________________________________
        Fiware-lab-help mailing list
        Fiware-lab-help@lists.fiware.org
        https://lists.fiware.org/listinfo/fiware-lab-help-new

        Show
        fw.ext.user FW External User added a comment - Dear Massimiliano and FINESCE team, I hope your review went quite well including the demonstration. If I understood well, this was FINESCE final review, so I think it is the right time to bring back a discussion that we already had in the past. The fact is that DCA/SBC (the old version of IDAS that you are using) is not supported since long time ago (>1 year) but we kept it only for your usage, so your could end the project up without disturbing too much. Today we really need to take an action on this so we all have two options depending on your needs: 1. If you think FINESCE infrastructure will be down in a reasonable time (say 1 month max) we can keep this instance and shut it down by Nov 1st. 2. If you think you will further be using IDAS you have to upgrade as soon as possible to the new architecture based on IoT Agents+ ContextBroker. This architecture and components is really stable (we use it in some Telefonica commercial projects too) and is extremely easier to use and exploit. In this preso you have the four easy steps to register and use devices. I can configure you a private instance ³finesce² to start testing. http://www.slideshare.net/FI-WARE/fiware-iotidasintroul20v2 Please, let us know your decision so we can proceed. Thanks a lot for your cooperation and Thanks for using IDAS! – --------------------------------------------------------------------------- --------------------------------------------- Carlos Ralli Ucendo (carlos.ralliucendo@telefonica.com) Cell: +34696923588 Twitter: @carlosralli Blog: http://the-internet6.blogspot.com.es < http://the-internet6.blogspot.com.es/ > Telefónica I+D SAU Madrid, Spain --------------------------------------------------------------------------- --------------------------------------------- Follow FIWARE project (Future Internet Services Core Platform): Website: http://www.fi-ware . < http://www.fi-ware.eu/ >org Facebook: http://www.facebook.com/pages/FI-WARE/251366491587242 Twitter: @fiware LinkedIn: http://www.linkedin.com/groups/FIWARE-4239932 --------------------------------------------------------------------------- --------------------------------------------- El 10/09/15 12:37, "Massimiliano Nigrelli" <massimiliano.nigrelli@eng.it> ________________________________ Este mensaje y sus adjuntos se dirigen exclusivamente a su destinatario, puede contener información privilegiada o confidencial y es para uso exclusivo de la persona o entidad de destino. Si no es usted. el destinatario indicado, queda notificado de que la lectura, utilización, divulgación y/o copia sin autorización puede estar prohibida en virtud de la legislación vigente. Si ha recibido este mensaje por error, le rogamos que nos lo comunique inmediatamente por esta misma vía y proceda a su destrucción. The information contained in this transmission is privileged and confidential information intended only for the use of the individual or entity named above. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this transmission in error, do not read it. Please immediately reply to the sender that you have received this communication in error and then delete it. Esta mensagem e seus anexos se dirigem exclusivamente ao seu destinatário, pode conter informação privilegiada ou confidencial e é para uso exclusivo da pessoa ou entidade de destino. Se não é vossa senhoria o destinatário indicado, fica notificado de que a leitura, utilização, divulgação e/ou cópia sem autorização pode estar proibida em virtude da legislação vigente. Se recebeu esta mensagem por erro, rogamos-lhe que nos o comunique imediatamente por esta mesma via e proceda a sua destruição _______________________________________________ Fiware-lab-help mailing list Fiware-lab-help@lists.fiware.org https://lists.fiware.org/listinfo/fiware-lab-help-new
        Hide
        fw.ext.user FW External User added a comment -

        hi all!

        Just to remind you that as long as the fiware-lab-help is in CC, all is
        being recorded in a public ticket. Also, the people on the list possibly
        do not have any chances of actually contributing to this discussion so I
        would remove them from the interaction and come back to them with final
        conclusions if something is needed from the support team.

        Regards,

        Miguel

        Please update your address book with my new e-mail address: miguel.carrillopacheco@telefonica.com

        ----------------------------------------------------------------------
        / _// Miguel Carrillo Pacheco
        _/ _/ _/ _/ Telefónica Distrito Telefónica
        / _//_/ _/ _/ Investigación y Edifico Oeste 1, Planta 6
        _/ _/ _/ _/ Desarrollo Ronda de la Comunicación S/N
        / _// 28050 Madrid (Spain)
        Tel: (+34) 91 483 26 77

        e-mail: miguel.carrillopacheco@telefonica.com

        Follow FIWARE on the net

        Website: http://www.fiware.org
        Facebook: https://www.facebook.com/eu.fiware
        Twitter: http://twitter.com/Fiware
        LinkedIn: https://www.linkedin.com/groups/FIWARE-4239932
        ----------------------------------------------------------------------

        ________________________________

        Este mensaje y sus adjuntos se dirigen exclusivamente a su destinatario, puede contener información privilegiada o confidencial y es para uso exclusivo de la persona o entidad de destino. Si no es usted. el destinatario indicado, queda notificado de que la lectura, utilización, divulgación y/o copia sin autorización puede estar prohibida en virtud de la legislación vigente. Si ha recibido este mensaje por error, le rogamos que nos lo comunique inmediatamente por esta misma vía y proceda a su destrucción.

        The information contained in this transmission is privileged and confidential information intended only for the use of the individual or entity named above. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this transmission in error, do not read it. Please immediately reply to the sender that you have received this communication in error and then delete it.

        Esta mensagem e seus anexos se dirigem exclusivamente ao seu destinatário, pode conter informação privilegiada ou confidencial e é para uso exclusivo da pessoa ou entidade de destino. Se não é vossa senhoria o destinatário indicado, fica notificado de que a leitura, utilização, divulgação e/ou cópia sem autorização pode estar proibida em virtude da legislação vigente. Se recebeu esta mensagem por erro, rogamos-lhe que nos o comunique imediatamente por esta mesma via e proceda a sua destruição
        _______________________________________________
        Fiware-lab-help mailing list
        Fiware-lab-help@lists.fiware.org
        https://lists.fiware.org/listinfo/fiware-lab-help-new

        Show
        fw.ext.user FW External User added a comment - hi all! Just to remind you that as long as the fiware-lab-help is in CC, all is being recorded in a public ticket. Also, the people on the list possibly do not have any chances of actually contributing to this discussion so I would remove them from the interaction and come back to them with final conclusions if something is needed from the support team. Regards, Miguel – Please update your address book with my new e-mail address: miguel.carrillopacheco@telefonica.com ---------------------------------------------------------------------- / _/ / Miguel Carrillo Pacheco _/ _/ _/ _/ Telefónica Distrito Telefónica / _/ /_/ _/ _/ Investigación y Edifico Oeste 1, Planta 6 _/ _/ _/ _/ Desarrollo Ronda de la Comunicación S/N / _/ / 28050 Madrid (Spain) Tel: (+34) 91 483 26 77 e-mail: miguel.carrillopacheco@telefonica.com Follow FIWARE on the net Website: http://www.fiware.org Facebook: https://www.facebook.com/eu.fiware Twitter: http://twitter.com/Fiware LinkedIn: https://www.linkedin.com/groups/FIWARE-4239932 ---------------------------------------------------------------------- ________________________________ Este mensaje y sus adjuntos se dirigen exclusivamente a su destinatario, puede contener información privilegiada o confidencial y es para uso exclusivo de la persona o entidad de destino. Si no es usted. el destinatario indicado, queda notificado de que la lectura, utilización, divulgación y/o copia sin autorización puede estar prohibida en virtud de la legislación vigente. Si ha recibido este mensaje por error, le rogamos que nos lo comunique inmediatamente por esta misma vía y proceda a su destrucción. The information contained in this transmission is privileged and confidential information intended only for the use of the individual or entity named above. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this transmission in error, do not read it. Please immediately reply to the sender that you have received this communication in error and then delete it. Esta mensagem e seus anexos se dirigem exclusivamente ao seu destinatário, pode conter informação privilegiada ou confidencial e é para uso exclusivo da pessoa ou entidade de destino. Se não é vossa senhoria o destinatário indicado, fica notificado de que a leitura, utilização, divulgação e/ou cópia sem autorização pode estar proibida em virtude da legislação vigente. Se recebeu esta mensagem por erro, rogamos-lhe que nos o comunique imediatamente por esta mesma via e proceda a sua destruição _______________________________________________ Fiware-lab-help mailing list Fiware-lab-help@lists.fiware.org https://lists.fiware.org/listinfo/fiware-lab-help-new
        Hide
        fw.ext.user FW External User added a comment -

        Dear Carlos, all,

        as suggested by Pasquale I would express our common view by asking you to
        keep active the IDAS with the SensorML until the end of the 2015.
        It seems that after the end of the project the FINESCE experimental facility
        will be down in a reasonable time, e.g. by December 31st.

        In FINESCE we created and deployed the “ETSI M2M compliant” software
        solution based on the IDAS/SensorML features prospected by the FI-WARE
        catalogue.
        In the metering scenario depicted by the most recent EU directive, the
        “UltraLight 2.0” is not mentioned as a metering protocol.
        Because of the above, there are no reasons for us to upgrade to the UL2.0:
        the DSOs could demand for the ETSI M2M/SensorML but they unlikely will
        demand for the UL2.0.

        By the way, the co-funding rate in FP7 was 75% (e.g. lower than 100%): we
        made an investment.
        Based on the articles from the EC contract, we should preserve our working
        baseline.
        Should you dismiss the IDAS 1.0 (SensorML) by December 31st, we would
        appreciate to get/download its source code, the ready-made binaries, and the
        current configuration in full in order to be able to replicate the fully
        working environment on our servers.

        Thank you for understanding. Yours, Mikhail Simonov

        Show
        fw.ext.user FW External User added a comment - Dear Carlos, all, as suggested by Pasquale I would express our common view by asking you to keep active the IDAS with the SensorML until the end of the 2015. It seems that after the end of the project the FINESCE experimental facility will be down in a reasonable time, e.g. by December 31st. In FINESCE we created and deployed the “ETSI M2M compliant” software solution based on the IDAS/SensorML features prospected by the FI-WARE catalogue. In the metering scenario depicted by the most recent EU directive, the “UltraLight 2.0” is not mentioned as a metering protocol. Because of the above, there are no reasons for us to upgrade to the UL2.0: the DSOs could demand for the ETSI M2M/SensorML but they unlikely will demand for the UL2.0. By the way, the co-funding rate in FP7 was 75% (e.g. lower than 100%): we made an investment. Based on the articles from the EC contract, we should preserve our working baseline. Should you dismiss the IDAS 1.0 (SensorML) by December 31st, we would appreciate to get/download its source code, the ready-made binaries, and the current configuration in full in order to be able to replicate the fully working environment on our servers. Thank you for understanding. Yours, Mikhail Simonov

          People

          • Assignee:
            ralli Carlos Ralli Ucendo
            Reporter:
            fw.ext.user FW External User
          • Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

            Dates

            • Created:
              Updated:
              Resolved: