Hi all,
I have made a verbose curl, and connection seems correctly made but response is empty
curl -v 130.206.82.78:1026/version
- About to connect() to 130.206.82.78 port 1026 (#0)
- Trying 130.206.82.78... connected
- Connected to 130.206.82.78 (130.206.82.78) port 1026 (#0)
- Empty reply from server
- Connection #0 to host 130.206.82.78 left intact
curl: (52) Empty reply from server
- Closing connection #0
Regards,
IDAS team
________________________________________
De: Massimiliano Nigrelli [massimiliano.nigrelli@eng.it]
Enviado: miércoles, 09 de septiembre de 2015 12:11
Para: e.idas1; Daniele Santoro; simonov@ismb.it
CC: CARLOS RALLI UCENDO; marco.paulucci; fiware-lab-help; gianluca.zanetto@teamware.it; Federico Rizzo; Pasquale Andriani; alessandro.gobbo
Asunto: Re: [Fiware-lab-help] URGENT: request for assistance; IDAS FINESCE dedicated instance
Dear all,
that ORION is up-and-running.
Look what i get locally:
curl localhost:1026/version
<orion>
<version>0.14.0</version>
<uptime>0 d, 0 h, 0 m, 58 s</uptime>
<git_hash>5e3d210e4b15fa9ebbfa07c93dd41f8b41697d0e</git_hash>
<compile_time>nodate</compile_time>
<compiled_by>fermin</compiled_by>
<compiled_in>centollo</compiled_in>
</orion>
More, I have tried your curl from a VM inside our area of oldcloud, and
it works:
curl 130.206.82.78:1026/version
<orion>
<version>0.14.0</version>
<uptime>0 d, 0 h, 4 m, 38 s</uptime>
<git_hash>5e3d210e4b15fa9ebbfa07c93dd41f8b41697d0e</git_hash>
<compile_time>nodate</compile_time>
<compiled_by>fermin</compiled_by>
<compiled_in>centollo</compiled_in>
</orion>
Is there any networking issue in the oldcloud due to which public ip is
not reachable from IDAS?
Yesterday oldaccount was down and I do not know if something has been
down since yesterday afternoon!
I am a bit worried
Regards,
Massimiliano
Il 09/09/2015 11:54, e.idas1 ha scritto:
–
===============================================================
Massimiliano Nigrelli
Direzione Ricerca e Innovazione - R&D Lab
massimiliano.nigrelli@eng.it
Engineering Ingegneria Informatica S.p.A.
Viale Regione Siciliana, 7275 - 90146 Palermo (Italy)
Phone: +39 091.75.11.847
============================================================
________________________________
Este mensaje y sus adjuntos se dirigen exclusivamente a su destinatario, puede contener información privilegiada o confidencial y es para uso exclusivo de la persona o entidad de destino. Si no es usted. el destinatario indicado, queda notificado de que la lectura, utilización, divulgación y/o copia sin autorización puede estar prohibida en virtud de la legislación vigente. Si ha recibido este mensaje por error, le rogamos que nos lo comunique inmediatamente por esta misma vía y proceda a su destrucción.
The information contained in this transmission is privileged and confidential information intended only for the use of the individual or entity named above. If the reader of this message is not the intended recipient, you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this transmission in error, do not read it. Please immediately reply to the sender that you have received this communication in error and then delete it.
Esta mensagem e seus anexos se dirigem exclusivamente ao seu destinatário, pode conter informação privilegiada ou confidencial e é para uso exclusivo da pessoa ou entidade de destino. Se não é vossa senhoria o destinatário indicado, fica notificado de que a leitura, utilização, divulgação e/ou cópia sem autorização pode estar proibida em virtude da legislação vigente. Se recebeu esta mensagem por erro, rogamos-lhe que nos o comunique imediatamente por esta mesma via e proceda a sua destruição
_______________________________________________
Fiware-lab-help mailing list
Fiware-lab-help@lists.fiware.org
https://lists.fiware.org/listinfo/fiware-lab-help-new
Dear Carlos, all,
as suggested by Pasquale I would express our common view by asking you to
keep active the IDAS with the SensorML until the end of the 2015.
It seems that after the end of the project the FINESCE experimental facility
will be down in a reasonable time, e.g. by December 31st.
In FINESCE we created and deployed the “ETSI M2M compliant” software
solution based on the IDAS/SensorML features prospected by the FI-WARE
catalogue.
In the metering scenario depicted by the most recent EU directive, the
“UltraLight 2.0” is not mentioned as a metering protocol.
Because of the above, there are no reasons for us to upgrade to the UL2.0:
the DSOs could demand for the ETSI M2M/SensorML but they unlikely will
demand for the UL2.0.
By the way, the co-funding rate in FP7 was 75% (e.g. lower than 100%): we
made an investment.
Based on the articles from the EC contract, we should preserve our working
baseline.
Should you dismiss the IDAS 1.0 (SensorML) by December 31st, we would
appreciate to get/download its source code, the ready-made binaries, and the
current configuration in full in order to be able to replicate the fully
working environment on our servers.
Thank you for understanding. Yours, Mikhail Simonov