Uploaded image for project: 'Help-Desk'
  1. Help-Desk
  2. HELP-622

FIWARE.Request.Tech.IoT.IDAS.MissingInfoMonit

    Details

    • HD-Chapter:
      IoT
    • HD-Enabler:
      IDAS

      Description

      There is no information on the installation guide on how to automate
      the start of the frontend and backend components of DCA-IDAS SE using
      monit. Following the method used for previous components, this could
      be done by adding to /etc/inittab the following lines:

      mfe:2345:respawn:su - mongodb -c "monit -v -I -c
      /export/open/IDAS_FE/conf/monitIDAS.conf -d 10 -p
      /export/open/IDAS_FE/run/monit.pid"
      mbe:2345:respawn:su - mongodb -c "monit -v -I -c
      /export/open/IDAS_BE/conf/monitIDAS.conf -d 10 -p
      /export/open/IDAS_BE/run/monit.pid"
      _______________________________________________
      Fiware-tech-help mailing list
      Fiware-tech-help@lists.fi-ware.org
      https://lists.fi-ware.org/listinfo/fiware-tech-help

        Activity

        There are no comments yet on this issue.

          People

          • Assignee:
            ralli Carlos Ralli Ucendo
            Reporter:
            fw.ext.user FW External User
          • Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

            Dates

            • Created:
              Updated:
              Resolved: