The neoidas-bd rpm package currently available has some errors that
need to be fixed:
- Set the user and group of files during package creation:
The files on the package have the group set to "idas" and the user
set to "manager", which may not exist when installing the package,
raising the following error:
warning: group idas does not exist - using root
warning: user manager does not exist - using root
This can be fixed when building the rpm package by using the %attr
and %defattr directives on the %files section of the package spec
file. If the user and group must exist, state on the installation
guide the necessary commands to create them.