Uploaded image for project: 'Help-Desk'
  1. Help-Desk
  2. HELP-6111

FIWARE.Request.Tech.Data.CEP.CEP - Proton: Event Processing Network Definition

    Details

    • Type: extRequest
    • Status: Closed
    • Priority: Major
    • Resolution: Done
    • Fix Version/s: 2021
    • Component/s: FIWARE-TECH-HELP
    • Labels:
      None

      Description

      I've installed the Proton GE and preformed a simple condition verification on an input event.
      My goal is to verify more complex conditions. For example: If the rain level on a period of 48 hours exceeds a limit.
      How can I define this verification?
      Thank you,
      JPedro Marques
      Since January 1st, old domains won't be supported and messages sent to any domain different to @lists.fiware.org will be lost.
      Please, send your messages using the new domain (Fiware-tech-help@lists.fiware.org) instead of the old one.
      _______________________________________________
      Fiware-tech-help mailing list
      Fiware-tech-help@lists.fiware.org
      https://lists.fiware.org/listinfo/fiware-tech-help
      [Created via e-mail received from: =?utf-8?Q?Jos=C3=A9_Pedro_P=C3=B3voa_Marques?= <jpmarques@ipn.pt>]

        Issue Links

          Activity

          Hide
          urishani Uri Shani added a comment -

          Dear J Pedro,
          I'd encourage you to look at the examples in the Proton (CEP) documentation. Your issues should be answered from that. Mind you that keeping a context for as long as 48 hours, depending on the volume of events being collected - may cause severe overloads on the server. Just that performance issues are not triggered in this way.
          See the documentation please: http://proactive-technology-online.readthedocs.org/en/latest/index.html

          Thanks,

          • Uri
          Show
          urishani Uri Shani added a comment - Dear J Pedro, I'd encourage you to look at the examples in the Proton (CEP) documentation. Your issues should be answered from that. Mind you that keeping a context for as long as 48 hours, depending on the volume of events being collected - may cause severe overloads on the server. Just that performance issues are not triggered in this way. See the documentation please: http://proactive-technology-online.readthedocs.org/en/latest/index.html Thanks, Uri
          Hide
          fw.ext.user FW External User added a comment -

          Hi,

          Is there any way to do it without causing severe overloads on the server?

          I’ve already read the documentation and I was not able to understand how to define a rule like that. If it was possible to show me an example where a rule of this kind is defined I would be grateful.

          Thank you,
          JPedro Marques

          Show
          fw.ext.user FW External User added a comment - Hi, Is there any way to do it without causing severe overloads on the server? I’ve already read the documentation and I was not able to understand how to define a rule like that. If it was possible to show me an example where a rule of this kind is defined I would be grateful. Thank you, JPedro Marques
          Hide
          urishani Uri Shani added a comment -

          Hi again,
          Asking our language expert to help here. Hope we get some answers soon.

          Thanks for your patience.

          • Uri
          Show
          urishani Uri Shani added a comment - Hi again, Asking our language expert to help here. Hope we get some answers soon. Thanks for your patience. Uri
          Hide
          urishani Uri Shani added a comment -

          Answered in stack overflow: http://stackoverflow.com/questions/36033941/cep-proton-complex-event-definition
          Related to HELP-6149. Hence, this issue is a duplicate of HELP-6149: https://jira.fiware.org/browse/HELP-6149.
          To be closed as such.

          Show
          urishani Uri Shani added a comment - Answered in stack overflow: http://stackoverflow.com/questions/36033941/cep-proton-complex-event-definition Related to HELP-6149 . Hence, this issue is a duplicate of HELP-6149 : https://jira.fiware.org/browse/HELP-6149 . To be closed as such.