      I cannot properly read Southbound commands through Orion to MQTT devices

      Description:
      I am trying to send commands in the Southbound direction following this flow:

      The commands supported by the devices are provisioned as follows:
      "services": [
      {
      "apikey": "5jggokgpepnvsb2uv4s40d59ov",
      "cbroker": "'"http://orion:$ORION_PORT"'",
      "entity_type": "Agv",
      "transport": "MQTT",
      "resource": "",
      "commands": [
      {
      "object_id": "AGV_Alarm",
      "name": "AGV_Alarm",
      "type": "command",
      "value":

      { "data": "metadata_for_AGV_Alarm" }

      },
      {
      "object_id": "AGV_Event",
      "name": "AGV_Event",
      "type": "command",
      "value":

      { "data": "metadata_for_AGV_Event" }

      }
      ],

      The request to send the command in the Southbound direction is made through the Orion Context Broker:
      curl -iX PATCH \
      'http://orion:1026/v2/entities/urn:ngsi-ld:Agv:001/attrs' \
      -H 'Content-Type: application/json' \
      -H 'fiware-service: openiot' \
      -H 'fiware-servicepath: /' \
      -d '{
      "AGV_Event":

      { "type" : "command", "value": "152" }

      }'

      To simulate actuators the following tool is used which is listening for commands via MQTT:
      docker run -it --rm --name mqtt-subscriber --network fiware_default efrecon/mqtt-client sub -h mosquitto -t "/5jggokgpepnvsb2uv4s40d59ov/agv001/cmd"

      I can receive only a part of the payload of the command:
      ubuntu@ip-172-31-85-246:~/FiwareDockerDevMode$ docker run -it --rm --name mqtt-subscriber --network fiware_default efrecon/mqtt-client sub -h mosquitto -t "/5jggokgpepnvsb2uv4s40d59ov/agv001/cmd"

      {"AGV_Event":""} {"AGV_Event":""} {"AGV_Event":""}

      In the temporary MongoDB, the command status appears as PENDING
      AGV_Event_status: {
      type: 'commandStatus',
      creDate: 1669583822.6813245,
      modDate: 1669584130.4993052,
      value: 'PENDING',
      mdNames: [
      'TimeInstant'
      ],
      md: {
      TimeInstant:

      { type: 'DateTime', value: 1669584130.495 }

      }
      },
      AGV_Event_info:

      { type: 'commandResult', creDate: 1669583822.6813245, modDate: 1669583822.6813245, value: ' ', mdNames: [] }

      ,

      Update
      If, on the other hand, I send the command according to the structure it has in MongoDB:
      curl -iX PATCH \
      'http://orion:1026/v2/entities/urn:ngsi-ld:Agv:001/attrs' \
      -H 'Content-Type: application/json' \
      -H 'fiware-service: openiot' \
      -H 'fiware-servicepath: /' \
      -d '{
      "AGV_Event_info":

      { "type": "commandResult", "value": "200" }

      ,
      "AGV_Event_status":

      { "type": "commandStatus", "value": "OK" }

      }'

      Now, nothing is received in the actuator simulator:
      ubuntu@ip-172-31-85-246:~/FiwareDockerDevMode$ docker run -it --rm --name mqtt-subscriber --network fiware_default efrecon/mqtt-client sub -h mosquitto -t "/5jggokgpepnvsb2uv4s40d59ov/agv001/cmd"

      However, the temporary MongoDB is updated properly:
      AGV_Event_status:

      { type: 'commandStatus', creDate: 1669731581.9883916, modDate: 1669733857.6557434, value: 'OK', mdNames: [] }

      ,
      AGV_Event_info:

      { type: 'commandResult', creDate: 1669731581.9883916, modDate: 1669733857.6557305, value: '200', mdNames: [] }

      ,

      The official documentation of the IoTAgent-JSON suggests that when commands are sent in the Southbound direction the actuator will send a response, which would make sense considering that my actuators are dummies.
      Any suggestions on how to receive all the information sent through the Orion Context Broker?