Description
Created question in FIWARE Q/A platform on 16-02-2021 at 10:02
Please, ANSWER this question AT https://stackoverflow.com/questions/66221917/adding-nested-opc-ua-variable-results-in-string-cannot-be-coerced-to-a-nodeid
Question:
adding nested OPC-UA Variable results in "String cannot be coerced to a nodeId"
Description:
Error: String cannot be coerced to a nodeId
Hi,
I was busy setting up a connection between the Orion Broker and an PLC with OPC-UA Server using the opcua iotagent agent.
I managed to setup all parts and I am able to receive (test) data, but I am unable to follow the tutorial with regards to adding an entity to the Orion-Broker using a json file:
curl http://localhost:4001/iot/devices -H "fiware-service: plcservice" -H "fiware-servicepath: /demo" -H "Content-Type: application/json" -d @add_device.json
The expected result would be an added entity to the OrionBroker with the supplied data, but this only results in a error message:
{"name":"Error","message":"String cannot be coerced to a nodeId : ns*4:s*MAIN.mainVar"}suspected Error
Is it possible that the iotagent does not work nicely with nested Variables?
steps taken
doublechecked availability of OPC Data:
OPC data changes every second, can be seen in Broker log
reduced complexity of setup to only include Broker and IOT-agent
additional information:
add_device.json file:
{
"devices": [
{
"device_id": "plc1",
"entity_name": "PLC1",
"entity_type": "plc",
"attributes": [
],
"lazy": [
],
"commands" : []
}
]
}
config of IOT-agent (from localhost:4081/config):
{
"config": {
"logLevel": "DEBUG",
"contextBroker":
,
"server":
,
"deviceRegistry":
,
"mongodb":
,
"types": {
"plc": {
"service": "plcservice",
"subservice": "/demo",
"active": [
,
,
{ "name": "test2", "type": "Int16" } ],
"lazy": [],
"commands": []
}
},
"browseServerOptions": null,
"service": "plc",
"subservice": "/demo",
"providerUrl": "http://iotage:4001",
"pollingExpiration": "200000",
"pollingDaemonFrequency": "20000",
"deviceRegistrationDuration": "P1M",
"defaultType": null,
"contexts": [
{
"id": "plc_1",
"type": "plc",
"service": "plcservice",
"subservice": "/demo",
"polling": false,
"mappings": [
,
,
{ "ocb_id": "main", "opcua_id": "ns=4;s=MAIN.mainVar", "object_id": null, "inputArguments": [] } ]
}
]
}
}
Activity
- All
- Comments
- History
- Activity
- Transitions
2021-02-17 09:06|CREATED monitor | # answers= 0, accepted answer= False